Correction - Actual Lack Of Reserve Level 1 (LOR1) in the SA Region.- 10/04/2018
Correction - Actual Lack Of Reserve Level 1 (LOR1) in the SA Region.- 10/04/2018
Refer AEMO Electricity Market Notice 61181
An Actual LOR1 condition has been declared for the SA Region from 1735 hrs.
The Actual LOR1 condition is forecast to exist until 2000 hrs
The contingency capacity reserve required is 600 MW
The minimum reserve available is 376 MW
Manager NEM Real Time Operations
Actual Lack Of Reserve Level 1 (LOR1) in the SA Region.- 10/04/2018
Actual Lack Of Reserve Level 1 (LOR1) in the SA Region.- 10/04/2018
Refer AEMO Electricity Market Notice 61181
An Actual LOR1 condition has been declared for the SA Region from 1735 hrs.
The Actual LOR1 condition is forecast to exist until 1700 hrs
The contingency capacity reserve required is 600 MW
The minimum reserve available is 376 MW
Manager NEM Real Time Operations
Updated generator combinations for SA system strength
Updated generator combinations for SA system strength
AEMO is continuing to investigate system strength requirements in South Australia.
Through this work, AEMO has identified one additional generator combination which meet minimum system strength requirements in South Australia.
This new combination is:
LOW_5B - 2 x Torrens Island A units + 3 x Torrens Island B units
Note: LOW_5 (3 x Torrens Island A units + 2 x Torrens Island B units) has been relabelled as LOW_5A
For more information refer to the updated limits advice:
https://www.aemo.com.au/-/media/Files/Electricity/NEM/Security_and_Reliability/Congestion-Information/2018/Transfer-Limit-Advice---South-Australian-System-Strength.pdf
A further update to this advice is planned by early May 2018.
Ben Blake
AEMO Operations
Updated generator combinations for SA system strength
Updated generator combinations for SA system strength
AEMO is continuing to investigate system strength requirements in South Australia.
Through this work, AEMO has identified three additional generator combinations which meet minimum system strength requirements in South Australia.
These new combinations are:
LOW_14 - 2 x Torrens Island A units + 1 x Torrens Island B units + 1 x Pelican Point GT/ST units
LOW_15 - 1 x Torrens Island A units + 1 x Torrens Island B units + 1 x Pelican Point GT/ST units + Quarantine 5 / 3 x Dry Creek units
LOW_16 - 3 x Torrens Island A units + 1 x Pelican Point GT/ST units + Osborne GT/ST
Note: LOW_14 replaces LOW_12.
For more information refer to the updated limits advice:
https://www.aemo.com.au/-/media/Files/Electricity/NEM/Security_and_Reliability/Congestion-Information/2017/Transfer-Limit-Advice---South-Australian-System-Strength.pdf
A further update to this advice is planned by late April/May 2018.
Ben Blake
AEMO Operations
Cancellation of Actual (LOR1) condition in the Qld region - 14/02/2018
Cancellation of Actual (LOR1) condition in the Qld region - 14/02/2018
The Actual LOR1 Condition in the Qld Region advised in AEMO Electricity Market Notice No.61252 is cancelled at 1930 hrs 14/02/2018.
Manager NEM Real Time Operations
Actual Lack Of Reserve Level 1 (LOR1) in the QLD Region.- 14/02/2018
Actual Lack Of Reserve Level 1 (LOR1) in the QLD Region.- 14/02/2018
Refer AEMO Electricity Market Notice 61251
An Actual LOR1 condition has been declared for the QLD Region from 1600 hrs.
The Actual LOR1 condition is forecast to exist until 1700 hrs
The contingency capacity reserve required is 1260 MW
The minimum reserve available is 1064 MW
Manager NEM Real Time Operations
Cancellation of Actual (LOR1) condition in the SA region - 07/02/2018
Cancellation of Actual (LOR1) condition in the SA region - 07/02/2018
The Actual LOR1 Condition in the SA Region advised in AEMO Electricity Market Notice No.61147 is cancelled at 2000 hrs 07/02/2018.
Manager NEM Real Time Operations
Cancellation of Actual (LOR1) condition in the Vic region - 07/02/2018
Cancellation of Actual (LOR1) condition in the Vic region - 07/02/2018
The Actual LOR1 Condition in the Vic Region advised in AEMO Electricity Market Notice No.61146 is cancelled at 1900 hrs 07/02/2018.
Manager NEM Real Time Operations
Actual Lack Of Reserve Level 1 (LOR1) in the SA Region.- 7/02/2018
Actual Lack Of Reserve Level 1 (LOR1) in the SA Region.- 7/02/2018
An Actual LOR1 condition has been declared for the SA Region from 1700 hrs.
The Actual LOR1 condition is forecast to exist until 1730 hrs
The contingency capacity reserve required is 600 MW
The minimum reserve available is 580 MW
Manager NEM Real Time Operations