Inter-regional transfer limit variation South Australia - 04 July 2016
Inter-regional transfer limit variation South Australia - 04 July 2016
A short notice outage of the Templers No.2 132 kV Transformer in the SA region has occurred at 0955 hrs.
The following constraint set has been invoked for this outage at 1005 hrs
S-X_TPRS+TPDR
The outage constraint set contains the following interconnector on the LHS
V-S-MNSP1
Refer to AEMO Network Outage Scheduler (NOS) for further details.
Manager NEM Real Time Operations
Inter-regional transfer limit variation - Lismore SVC - NSW Region - Sun 3 July 2016
Inter-regional transfer limit variation - Lismore SVC - NSW Region - Sun 3 July 2016
At 2247 hrs, an unplanned outage of the Lismore SVC occured.
The following constraint set was invoked from 2255 hrs.
N-LS_VC1
The constraint set contains equations with the following interconnectors on the LHS.
N-Q-MNSP1
NSW1_QLD1
See Network Outage Scheduler (NOS) for further details and return to service times.
Manager NEM Real Time Operations
Update: Forecast Lack Of Reserve Level 1(LOR1) in the South Australia region - STPASA
RE: AEMO Electricity Market Notice No. 54201
NOTICE OF UPDATE
AEMO declares a Forecast LOR1 condition for the South Australia region for the following period(s):
1. From 06/07/2016 1830 hrs to 2100 hrs
The minimum reserve available is 285 MW.
2. From 07/07/2016 1830 hrs to 2030 hrs
The minimum reserve available is 289 MW.
3. From 08/07/2016 1830 hrs to 2000 hrs
The minimum reserve available is 316 MW.
The contingency capacity reserve required over the above periods of forecast LOR1 conditions is 400 MW.
Manager NEM Real Time Operations
Inter-regional transfer limit variation George Town - Sheffield No2 220kV line (TAS)
Inter-regional transfer limit variation George Town - Sheffield No.2 220kV line (TAS).
An unplanned notice outage of the George Town - Sheffield No.2 220kV line (TAS) occurred at 0802 hrs Sunday, 3 July 2016.
Constraint Set T-GTSH invoked at 0810 hrs.
This Constraint Set contains an equation with the following interconnector on the LHS.
T-V-MNSP1
Refer to the Network Outage Schedule (NOS) for further details.
Power System Operations Manager
Update: Forecast Lack Of Reserve Level 1(LOR1) in the South Australia region - STPASA
RE: AEMO Electricity Market Notice No. 54188
NOTICE OF UPDATE
AEMO declares a Forecast LOR1 condition for the South Australia region for the following period(s):
1. From 04/07/2016 0830 hrs to 1000 hrs
The minimum reserve available is 308 MW.
2. From 06/07/2016 1830 hrs to 2000 hrs
The minimum reserve available is 345 MW.
3. From 07/07/2016 1830 hrs to 2000 hrs
The minimum reserve available is 326 MW.
4. From 08/07/2016 1900 hrs to 1930 hrs
The minimum reserve available is 368 MW.
The contingency capacity reserve required over the above periods of forecast LOR1 conditions is 400 MW.
Manager NEM Real Time Operations
Inter-Regional Transfer Limit Variation New South Wales Region Friday, 1 July 2016 Directlink
Inter-Regional Transfer Limit Variation New South Wales Region Friday, 1 July 2016 Directlink
An unplanned outage of the No 2 Leg of Directlink has occurred at 1859 hrs
See AEMO Network Outage Scheduler (NOS) for details.
The following constraint set is invoked for this outage from 1905 hrs
N-X_MBTE_2
The outage constraint set contains the following interconnector on the left hand side.
N-Q-MNSP1
Manager NEM Real Time Operations
Update: Forecast Lack Of Reserve Level 1(LOR1) in the South Australia region - STPASA - 4, 6 and 7 July 2016
RE: AEMO Electricity Market Notice(s) No. 54183.
NOTICE OF UPDATE
AEMO declares a Forecast LOR1 condition for the South Australia region for the following period(s):
1. From 04/07/2016 1800 hrs to 1900 hrs
The minimum reserve available is 365 MW.
2. From 06/07/2016 1800 hrs to 2100 hrs
The minimum reserve available is 273 MW.
3. From 07/07/2016 1800 hrs to 2100 hrs
The minimum reserve available is 217 MW.
The contingency capacity reserve required over the above periods of forecast LOR1 conditions is 400 MW.
Harmohan Singh
Operations Planning
Cancellation - Inter-regional Transfer Limit Variation - Hazelwood Rowville No.3 500 kV Transmission line Victoria region Thursday, 30 June 2016
Cancellation - Inter-regional Transfer Limit Variation - Hazelwood Rowville No.3 500 kV Transmission line Victoria region Thursday, 30 June 2016
Refer Electricity Market Notice 54182
The Hazelwood Rowville No. 3 500 kV Transmission line has been returned to service at 1638 hrs.
Refer to the NOS for details.
The following outage constraint set has be revoked at 1650 hrs.
V-HWRO3
The outage constraint contains the following interconnectors on the LHS
NSW-QLD1
T-V-MNSP1
V-S-MNSP1
V-SA
VIC1-NSW1
Power System Operations Manager
Update: Forecast Lack Of Reserve Level 1(LOR1) in the South Australia region - STPASA - 6 July 2016
RE: AEMO Electricity Market Notice No. 54173 & 54178.
NOTICE OF UPDATE
AEMO declares a Forecast LOR1 condition for the South Australia region for the following period:
From 06/07/2016 1800 hrs to 2030 hrs
The contingency capacity reserve required is 400 MW.
The minimum reserve available is 296 MW.
Harmohan Singh
Operations Planning