Market Notices

82271GENERAL NOTICE21/01/2021 10:25:37 AM

NEM Local Temperature Alerts for SA, VIC from 21 Jan 2021 to 25 Jan 2021

AEMO ELECTRICITY MARKET NOTICE

AEMO's weather service provider has issued forecast temperatures equal to or greater than the NEM Local Temperature Alert Levels for listed weather stations below.

SA
Adelaide West Terrace (39+ Deg C): 24th Jan
Clare High School (39+ Deg C): 23rd Jan, 24th Jan
Mt Gambier Ap (39+ Deg C): 24th Jan
Port Augusta Ap (39+ Deg C): 21st Jan, 23rd Jan, 24th Jan

VIC
Ararat Prison (39+ Deg C): 24th Jan
Latrobe Valley Ap (39+ Deg C): 25th Jan
Melbourne Olympic Park (39+ Deg C): 25th Jan
Mildura Ap (39+ Deg C): 22nd Jan, 23rd Jan, 24th Jan, 25th Jan

The NEM Local Temperature Alert Levels are:

Launceston Ti Tree Bend: 33 Deg C, Dalby Airport: 37 Deg C, for all other selected weather stations: 39 Deg C.

AEMO requests Market Participants to:

1. review the weather forecast in the local area where their generating units / MNSP converter stations are located and,

2. if required, update the available capacity in their dispatch offers or availability submissions consistent with the forecast temperatures.

Further information is available at:

https://aemo.com.au/energy-systems/electricity/national-electricity-market-nem/nem-forecasting-and-planning/forecasting-and-reliability/projected-assessment-of-system-adequacy/nem-local-temperature-alerts

AEMO Operations Planning
     
82270GENERAL NOTICE21/01/2021 06:55:56 AM

Planned outage of Moorabool - Haunted Gully and Haunted Gully - Tarrone 500 kV lines in the Victoria region from the 25 February 2021 - 3 March 2021

AEMO ELECTRICITY MARKET NOTICE

The Moorabool - Haunted Gully and Haunted Gully - Tarrone 500 kV lines in the Victoria (VIC) region is planned to be out of service from 25 February 2021 0500hrs - 3 March 2021 1730hrs.

A credible contingency event during this planned outage could cause synchronous separation of the South Australia (SA) region from the rest of the NEM. If separation occurs, load may be interrupted due to the operation of the Automatic Under Frequency Load Shedding (AUFLS) scheme in SA.

The credible separation contingency is managed as follows:

- When power transfer is from SA to Victoria, contingency lower FCAS will be sourced from SA.
- When power transfer is from Victoria to SA, due to the 47-52Hz island separation frequency band advised by the SA jurisdiction, contingency raise FCAS is not sourced in SA and the AUFLS scheme may respond to low frequency events.
- Power transfer will be restricted on Victoria - South Australia interconnector (Heywood interconnector) to manage system security following the loss of the next contingency.

Forecast capacity reserves in the SA region are currently sufficient to meet electricity demand during the planned outage.

The following constraint sets have been invoked for this outage:

I-VS_050
S-X_BC_CP
V-X_HG_ML_TR

Refer to AEMO Network Outage Schedule (NOS) for further details.

Diyoni Hoole
AEMO Operations
     
82269RECLASSIFY CONTINGENCY21/01/2021 01:05:00 AM

Cancellation of a Non-Credible Contingency Event: Condabri Nth - Condabri Central 7400 132kV line and Condabri Nth - Condabri Central 7401 132kV line in QLD1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Cancellation of reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits is no longer reasonably possible. There is no longer any lightning activity in the vicinity of the following lines. Accordingly its classification has reverted to a non-credible contingency event.

Region: QLD1

Lines: Condabri Nth - Condabri Central 7400 132kV and Condabri Nth - Condabri Central 7401 132kV

Cancellation time: 21/01/2021 01:04

Constraint set(s) revoked:
NONE

Refer AEMO Electricity Market Notice 82268

Auto-generated on behalf of Manager NEM Real Time Operations
     
82268RECLASSIFY CONTINGENCY21/01/2021 12:00:55 AM

Reclassification of a Non-Credible Contingency Event: Condabri Nth - Condabri Central 7400 132kV line and Condabri Nth - Condabri Central 7401 132kV line in QLD1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits to now be more likely and reasonably possible. Accordingly AEMO has reclassified it as a credible contingency event.

Region: QLD1

Lines: Condabri Nth - Condabri Central 7400 132kV and Condabri Nth - Condabri Central 7401 132kV

Duration: 21/01/2021 00:00 until further notice

Constraint set(s) invoked:
NONE

Auto-generated on behalf of Manager NEM Real Time Operations
     
82267RECLASSIFY CONTINGENCY20/01/2021 08:37:50 PM

Cancellation of a Non-Credible Contingency Event: Bulli Creek - Dumaresq 8L 330KV line and Bulli Creek - Dumaresq 8M 330KV line in QLD1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Cancellation of reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits is no longer reasonably possible. There is no longer any lightning activity in the vicinity of the following lines. Accordingly its classification has reverted to a non-credible contingency event.

Region: QLD1

Lines: Bulli Creek - Dumaresq 8L 330KV and Bulli Creek - Dumaresq 8M 330KV

Cancellation time: 20/01/2021 20:37

Constraint set(s) revoked:
I-QNI_ONE_PHASE_N-2 Constraint set contains the following interconnector(s) on the left hand side:
NSW1-QLD1


Refer AEMO Electricity Market Notice 82264

Auto-generated on behalf of Manager NEM Real Time Operations
     
82265MARKET INTERVENTION20/01/2021 05:10:37 PM

Direction - SA Region - 20/01/2021

AEMO ELECTRICITY MARKET NOTICE.

Direction - SA Region - 20/01/2021

In accordance with section 116 of the National Electricity Law, AEMO has issued a direction to a participant in the SA region. For the purposes of the National Electricity Rules this is a direction under clause 4.8.9(a).

The direction was necessary to maintain the power system in a secure operating state.

AEMO may issue or revoke additional directions in order to meet the current requirement, unless sufficient market response is provided. A further market notice will be issued when all directions related to this requirement have been cancelled.

The issue of the direction commences an AEMO intervention event. AEMO declares all dispatch intervals during the event to be intervention dispatch intervals, commencing from the interval ending 1715 hrs on 20/01/2021.

Intervention pricing does not apply to this AEMO intervention event.

Manager NEM Real Time Operations
     
82264RECLASSIFY CONTINGENCY20/01/2021 03:09:05 PM

Reclassification of a Non-Credible Contingency Event: Bulli Creek - Dumaresq 8L 330KV line and Bulli Creek - Dumaresq 8M 330KV line in QLD1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits to now be more likely and reasonably possible. Accordingly AEMO has reclassified it as a credible contingency event.

Region: QLD1

Lines: Bulli Creek - Dumaresq 8L 330KV and Bulli Creek - Dumaresq 8M 330KV

Duration: 20/01/2021 15:09 until further notice

Constraint set(s) invoked:
I-QNI_ONE_PHASE_N-2 Constraint set contains the following interconnector(s) on the left hand side:
NSW1-QLD1


Auto-generated on behalf of Manager NEM Real Time Operations
     
82263RECLASSIFY CONTINGENCY20/01/2021 02:14:35 PM

Cancellation of a Non-Credible Contingency Event: Chalumbin - Turkinje No.7165 132 kV line and Chalumbin - Turkinje No.7166 132 kV line in QLD1 due to Lightning.

AEMO ELECTRICITY MARKET NOTICE

Cancellation of reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits is no longer reasonably possible. There is no longer any lightning activity in the vicinity of the following lines. Accordingly its classification has reverted to a non-credible contingency event.

Region: QLD1

Lines: Chalumbin - Turkinje No.7165 132 kV and Chalumbin - Turkinje No.7166 132 kV

Cancellation time: 20/01/2021 14:14

Constraint set(s) revoked:
NONE

Refer AEMO Electricity Market Notice 82260

Auto-generated on behalf of Manager NEM Real Time Operations
     
82262MARKET INTERVENTION20/01/2021 02:32:30 PM

Cancellation - AEMO Intervention Event - Intervention dispatch intervals - Direction SA region - 17/01/2021

AEMO ELECTRICITY MARKET NOTICE

Cancellation - AEMO Intervention Event - Intervention dispatch intervals - Direction SA region - 17/01/2021

Refer Market Notice 82209

The AEMO Intervention Event and all associated directions are cancelled from 1430 hrs 20/01/2021

Manager NEM Real Time Operations
     
X