Filter by category
Filter by Date
STPASA - Cancellation of the Forecast Lack Of Reserve Level 3 (LOR3) in the SA Region on 15/08/2022
The Forecast LOR3 condition in the SA region on 15/08/2022 advised in AEMO Electricity Market Notice No. 100822 is cancelled at 1000 hrs 10/08/2022.
AEMO Operations
STPASA - Forecast Lack Of Reserve Level 3 (LOR3) in the SA Region on 15/08/2022
AEMO declares a Forecast LOR3 condition under clause 4.8.4(b) of the National Electricity Rules for the SA region for the following period:
From 1800 hrs 15/08/2022 to 1830 hrs 15/08/2022.
The maximum load (other than interruptible loads) forecast to be interrupted is 5 MW at 1800 hrs.
AEMO is seeking a market response.
AEMO has not yet estimated the latest time it would need to intervene through an AEMO intervention event.
AEMO Operations
STPASA - Cancellation of the Forecast Lack Of Reserve Level 3 (LOR3) in the SA Region on 29/06/2022
The Forecast LOR3 condition in the SA region on 29/06/2022 advised in AEMO Electricity Market Notice No. 99700 is cancelled at 1400 hrs 27/06/2022.
AEMO Operations
STPASA - Forecast Lack Of Reserve Level 3 (LOR3) in the SA Region on 29/06/2022
AEMO declares a Forecast LOR3 condition under clause 4.8.4(b) of the National Electricity Rules for the SA region for the following period:
From 1800 hrs to 1830 hrs 29/06/2022.
The maximum load (other than interruptible loads) forecast to be interrupted is 34 MW at 1800 hrs.
AEMO is seeking a market response.
AEMO has not yet estimated the latest time it would need to intervene through an AEMO intervention event.
AEMO Operations
Update to SA to Victoria limits for Para SVC outage
AEMO has been working with ElectraNet on a review of the oscillatory stability limits for the Para SVC outage for flows from South Australia to Victoria.
From that review the these limits from SA to Vic have been increased by 50 MW. The limit on Heywood has changed to 470 MW and for Heywood + Murraylink to 620 MW when the oscillatory stability monitoring is in service. If oscillatory monitoring is not in service the 50 MW increase will not apply.
The revised constraints were implemented in the constraint set S-PA_VC1 at 1300 hrs Friday 24th June 2022:
S:VS_PASVC_570OSC_AT
S:VS_PA_SVC_620
S:V_PASVC_420OSC_AT
S:V_PA_SVC_470
SV_470_DYN
AEMO and ElectraNet are continuing their studies on the limits for the Para SVC outage to determine if further increases can be made.
For further details on this this change please contact ben.blake@aemo.com.au
Ben Blake
AEMO Operations
STPASA - Cancellation of the Forecast Lack Of Reserve Level 3 (LOR3) in the SA Region on 30/06/2022
The Forecast LOR3 condition in the SA region on 30/06/2022 advised in AEMO Electricity Market Notice No. 99072 is cancelled at 0720 hrs 24/06/2022.
Manager NEM Real Time Operations
STPASA - Forecast Lack Of Reserve Level 3 (LOR3) in the SA Region on 30/06/2022
AEMO declares a Forecast LOR3 condition under clause 4.8.4(b) of the National Electricity Rules for the SA region for the following period:
From 0730 hrs 30/06/2022 to 0930 hrs 30/06/2022.
The maximum load (other than interruptible loads) forecast to be interrupted is 151 MW at 0800 hrs.
AEMO is seeking a market response.
AEMO has not yet estimated the latest time it would need to intervene through an AEMO intervention event.
AEMO Operations
STPASA - Cancellation of the Forecast Lack Of Reserve Level 3 (LOR3) in the SA Region beginning on 29/06/2022
The Forecast LOR3 condition in the SA region beginning on 29/06/2022 advised in AEMO Electricity Market Notice No.98897 is cancelled at 1000 hrs 23/06/2022.
AEMO Operations
STPASA - Update of the Forecast Lack Of Reserve Level 3 (LOR3) in the SA Region on 29/06/2022
The Forecast LOR3 Condition in the SA Region advised in AEMO Electricity Market Notice No.98856 has been updated at 1800 hrs 22/06/2022 to the following:
From 1730 hrs 29/06/2022 to 1830 hrs 29/06/2022.
The maximum load (other than interruptible loads) forecast to be interrupted is 185 MW at 1800 hrs.
AEMO is seeking a market response.
AEMO has not yet estimated the latest time it would need to intervene through an AEMO intervention event.
AEMO Operations