Market Notices

56554RESERVE NOTICE01/01/2017 01:02:58 AM

Forecast Lack Of Reserve Level 2 (LOR2) in the SA region - STPASA - 06/01/2017

AEMO ELECTRICITY MARKET NOTICE

Forecast Lack Of Reserve Level 2 (LOR2) in the SA region - STPASA - 06/01/2017

AEMO declares a Forecast LOR2 condition for the SA region.
From 1630 hrs to 1700 hrs 06/01/2017
The contingency capacity reserve required is 200 MW
The minimum reserve available is 195 MW

AEMO is seeking a market response.
AEMO will determine the latest time at which it would need to intervene through a AEMO intervention event.


Manager NEM Real Time Operations
56410RESERVE NOTICE23/12/2016 01:37:39 PM

Cancellation - Actual LOR2 South Australia Region - 23/12/2016

AEMO ELECTRICITY MARKET NOTICE

Cancellation - Actual LOR2 South Australia Region - 23/12/2016

Refer AEMO Electricity Market Notices 56398 and 56405

An actual LOR2 condition has been cancelled for the South Australia region from 1330 hrs


Manager NEM Real Time Operations
56405RESERVE NOTICE23/12/2016 07:26:01 AM

Actual LOR2 South Australia Region - 23/12/2016

AEMO ELECTRICITY MARKET NOTICE

Actual LOR2 South Australia Region - 23/12/2016

Refer AEMO Electricity Market Notice 56398

An actual LOR2 condition has been declared for the South Australia region from 0715 hrs and is forecast to continue until 1330 hrs 23/12/16 during a planned outage of the Moorabool - Mortlake PS 500k V Line in Victoria

If a credible contingency event occurs in this period the South Australia region would separate from the rest of the NEM and is likely to result in interruptions to power supplies.

There are sufficient capacity reserves in the South Australia region to meet electricity demand but it may not be possible to bring the required additional capacity into service in time to avoid automatic under-frequency load shedding causing power interruptions.

Manager NEM Real Time Operations
56398RESERVE NOTICE22/12/2016 02:36:34 PM

Forecast Lack Of Reserve Level 2 (LOR2) in South Australia region - 23/12/16

AEMO ELECTRICITY MARKET NOTICE

Refer to AEMO Electricity Market Notice 56397

Forecast Lack Of Reserve Level 2 (LOR2) in South Australia Region - from 0700 hrs to 1330 hrs on 23/12/2016.

AEMO declares a Forecast LOR2 condition for the South Australia region during the short notice outage of the Moorabool - Mortlake PS 500 kV Line in Victoria region, from 0700 hrs to 1330 hrs 23/12/16.

On the occurrence of a credible contingency during this planned outage, South Australia region could separate from the rest of the NEM and is likely to result in interruptions to power supplies in South Australia.

There are sufficient capacity reserves in the South Australia region to meet electricity demand but following the next credible contingency it may not be possible to bring the required additional capacity into service in time to avoid automatic under-frequency load shedding causing interruptions to power supplies in South Australia.

Manager NEM Real Time Operations

56391RESERVE NOTICE22/12/2016 01:20:44 PM

Cancellation of the Actual (LOR2) condition in the South Australia Region- 22/12/16

AEMO ELECTRICITY MARKET NOTICE

Cancellation of the Actual (LOR2) condition in the South Australia Region- 22/12/16

Refer to AEMO Electricity Market Notice No. 56388

The Actual LOR2 condition in the South Australia Region is cancelled at 1311 hrs 22/12/16

Manager NEM Real Time Operations
56388RESERVE NOTICE22/12/2016 06:08:22 AM

Actual LOR2 South Australia Region - 22/12/2016

AEMO ELECTRICITY MARKET NOTICE

Actual LOR2 South Australia Region - 22/12/2016

Refer AEMO Electricity Market Notice 56380

An actual LOR2 condition has been declared for the South Australia region from 0600 hrs and is forecast to continue until 1530 hrs 22/12/16 during a planned outage of the Heywood - Tarrone PS 500k V Line in Victoria

If a credible contingency event occurs in this period the South Australia region would separate from the rest of the NEM and is likely to result in interruptions to power supplies.

There are sufficient capacity reserves in the South Australia region to meet electricity demand but it may not be possible to bring the required additional capacity into service in time to avoid automatic under-frequency load shedding causing power interruptions.

Manager NEM Real Time Operations
56380RESERVE NOTICE21/12/2016 04:09:02 PM

Forecast Lack Of Reserve Level 2 (LOR2) in South Australia region - 22/12/16


AEMO ELECTRICITY MARKET NOTICE

Refer to AEMO Electricity Market Notice 56379

Forecast Lack Of Reserve Level 2 (LOR2) in South Australia Region - from 0600 hrs to 1530 hrs on 22/12/2016.

AEMO declares a Forecast LOR2 condition for the South Australia region during the planned outage of Heywood - Tarrone PS 500k V line in Victoria region, from 0600 hrs to 1530 hrs 22/12/2016.

On the occurrence of a credible contingency during this planned outage, South Australia region could separate from the rest of the NEM and is likely to result in interruptions to power supplies in South Australia.

There are sufficient capacity reserves in the South Australia region to meet electricity demand but following the next credible contingency it may not be possible to bring the required additional capacity into service in time to avoid automatic under-frequency load shedding causing interruptions to power supplies in South Australia.

Manager NEM Real Time Operations
56278RESERVE NOTICE15/12/2016 02:17:40 PM

Cancellation of the Actual (LOR2) condition in the South Australia region.

AEMO ELECTRICITY MARKET NOTICE

Cancellation of the Actual (LOR2) condition in the South Australia region.

Refer to AEMO Electricity Market Notice No. 56267

The Actual LOR2 condition in the South Australia Region is cancelled at 1407 hrs Thursday, 15 December 2016

Manager NEM Real Time Operations

56267RESERVE NOTICE14/12/2016 06:31:17 AM

Actual LOR2 South Australia Region - Wednesday, 14 December 2016

AEMO ELECTRICITY MARKET NOTICE

Actual LOR2 South Australia Region - Wednesday, 14 December 2016

Refer AEMO Electricity Market Notice 66225

An Actual LOR2 condition has been declared for the South Australia region from 0600 hrs and is forecast to continue until 2330 hrs Wednesday 14th December 2016 during a planned outage of Heywood No.1 500 kV busbar in the Victoria region.

On the occurrence of a credible contingency during this planned outage, South Australia region could separate from the rest of the NEM and is likely to result in interruptions to power supplies in South Australia.

There are sufficient capacity reserves in the South Australia region to meet electricity demand but it may not be possible to bring the required additional capacity into service in time to avoid automatic under-frequency load shedding causing power interruptions.


Manager NEM Real Time Operations