109383INTER-REGIONAL TRANSFER18/08/2023 06:42:03 PM

Inter-regional transfer limit variation - Tamworth SVC - NSW region - 18/08/2023

AEMO ELECTRICITY MARKET NOTICE

Inter-regional transfer limit variation - Tamworth SVC - NSW region - 18/08/2023

At 1820 hrs 18/08/2023 there was a short notice outage of the Tamworth SVC.

The following constraint set(s) invoked at 1820 hrs 18/08/2023
N-TW_SVC and N-X_LS+TW_SVC

This constraint set(s) contains equations with the following interconnectors on the LHS.
N-Q-MNSP1,NSW1-QLD1

Refer to the AEMO Network Outage Scheduler for further information.

Manager NEM Real Time Operations
109362INTER-REGIONAL TRANSFER17/08/2023 05:51:46 PM

Inter-regional transfer limit variation - Tamworth No.1 330 kV SVC- NSW region - 17/08/2023

AEMO ELECTRICITY MARKET NOTICE

Inter-regional transfer limit variation - Tamworth No.1 330 kV SVC- NSW region - 17/08/2023

At 1727 hrs 17/08/2023 there was an unplanned outage of Tamworth No.1 330 kV SVC.

The following constraint set(s) invoked at 1740 hrs 17/08/2023
N-TW_SVC
N-X_LS+TW_SVC

This constraint set(s) contains equations with the following interconnectors on the LHS.
N-Q-MSNP1
NSW1-QLD1

Refer to the AEMO Network Outage Scheduler for further information.

Manager NEM Real Time Operations
109318INTER-REGIONAL TRANSFER14/08/2023 04:17:55 PM

Inter-regional transfer limit variation - SESS CB6611 - SA region - 14/08/2023

AEMO ELECTRICITY MARKET NOTICE

Inter-regional transfer limit variation - SESS CB6611 - SA region - 14/08/2023

At 1630 hrs 14/08/2023 there is a short notice outage of SESS CB6611.

The following constraint set(s) invoked at 1630 hrs 14/08/2023
S-SECB6611_10_BC-2CP

This constraint set(s) contains equations with the following interconnectors on the LHS.
V-SA

Refer to the AEMO Network Outage Scheduler for further information.

Manager NEM Real Time Operations
109310INTER-REGIONAL TRANSFER14/08/2023 11:44:55 AM

Update - Inter-regional transfer limit variation - Georgetown - Comalco No 5 220kV Line - TAS region - 14/08/2023

AEMO ELECTRICITY MARKET NOTICE

Update - Inter-regional transfer limit variation - Georgetown - Comalco No 5 220kV Line - TAS region - 14/08/2023

At 0850 hrs 14/08/2023 there was an unplanned outage of Georgetown - Comalco No 5 220kV Line.

The following constraint set(s) invoked at 0900 hrs 14/08/2023
F-T-CSGO

This constraint set(s) contains equations with the following interconnectors on the LHS.
T-V-MNSP1


Refer to the AEMO Network Outage Scheduler for further information.

Manager NEM Real Time Operations
109309INTER-REGIONAL TRANSFER14/08/2023 11:41:21 AM

Inter-regional transfer limit variation - Georgetown - Comalco No 5 220kV Line - TAS region - 14/08/2023

AEMO ELECTRICITY MARKET NOTICE

Inter-regional transfer limit variation - Georgetown - Comalco No 5 220kV Line - TAS region - 14/08/2023

At 0850 hrs 14/08/2023 there was an unplanned outage of Georgetown - Comalco No 5 220kV Line.

The following constraint set(s) invoked at 0800 hrs 25/09/2023
F-T-CSGO

This constraint set(s) contains equations with the following interconnectors on the LHS.
T-V-MNSP1


Refer to the AEMO Network Outage Scheduler for further information.

Manager NEM Real Time Operations
109168INTER-REGIONAL TRANSFER02/08/2023 07:54:11 AM

Inter-regional transfer limit variation - Comalco substation CB 752 - TAS region - 02/08/2023

AEMO ELECTRICITY MARKET NOTICE

Inter-regional transfer limit variation - Comalco substation CB 752 - TAS region - 02/08/2023

There is a short notice outage at Comalco substation of CB 752.

Constraint set invoked: F-T-CO_CB752 invoked at 0740 hrs 02/08/2023

This constraint set(s) contains equations with the following interconnectors on the LHS.

T-V-MNSP1

Refer to the AEMO Network Outage Scheduler for further information.

Manager NEM Real Time Operations
109141INTER-REGIONAL TRANSFER31/07/2023 12:56:58 PM

Inter-regional transfer limit variation - Para 275kV East Bus Right Section - SA Region - 31/07/2023

AEMO ELECTRICITY MARKET NOTICE

Inter-regional transfer limit variation - Para 275kV East Bus Right Section - SA Region - 31/07/2023

At 1300 hrs 31/07/2023 there will be a short notice outage of Para 275kV East Bus Right Section.

The following constraint set invoked at 1300 hrs 31/07/2023.
S-PA_EAST_BUS_R

This constraint set contains equations with the following interconnectors on the LHS.

V-S-MNSP1
V-SA

Refer to AEMO Network Outage Scheduler (NOS) for further details.

Manager NEM Real Time Operations
109038INTER-REGIONAL TRANSFER25/07/2023 04:06:05 PM

Inter-regional transfer limit variation - Greenbank 275kV SVC - QLD region - 25/07/2023

AEMO ELECTRICITY MARKET NOTICE

Inter-regional transfer limit variation - Greenbank 275kV SVC - QLD region - 25/07/2023

At 1547 hrs 25/07/2023 there was an unplanned outage of Greenbank 275 kV SVC

The following constraint set(s) invoked at 1555 hrs 25/07/2023:
Q-GB_VC

This constraint set(s) contains equations with the following interconnectors on the LHS.

N-Q-MNSP1
NSW1 - QLD1

Refer to the AEMO Network Outage Scheduler for further information.

Manager NEM Real Time Operations
109034INTER-REGIONAL TRANSFER25/07/2023 07:40:33 AM

Inter-regional transfer limit variation - Wemen No.1 220kV Bus - VIC region - 25/07/2023

AEMO ELECTRICITY MARKET NOTICE

Inter-regional transfer limit variation - Wemen No.1 220kV Bus - VIC region - 25/07/2023

A planned outage of Wemen No.1 220kV Bus in the VIC region was scheduled from 0700 hrs 25/07/2023 to 1800 hrs 25/07/2023.

The outage has been cancelled.

Constraint set(s) invoked: V-KG_WE_RC

This constraint set(s) contains equations with the following interconnectors on the LHS.

T-V-MNSP1
V-SA
V-S-MNSP1
VIC1- NSW1

Refer to the AEMO Network Outage Scheduler for further information.

Manager NEM Real Time Operations