Filter by category
Filter by Date
STPASA - Forecast Lack Of Reserve Level 2 (LOR2) in the NSW Region on 18/06/2025
AEMO declares a Forecast LOR2 condition under clause 4.8.4(b) of the National Electricity Rules for the NSW region for the following period:
From 1730 hrs to 1900 hrs 18/06/2025.
The forecast capacity reserve requirement is 1047 MW.
The minimum capacity reserve available is 957 MW.
AEMO is seeking a market response.
AEMO has not yet estimated the latest time it would need to intervene through an AEMO intervention event.
AEMO Operations
[EventId:202506170825_review] Prices for interval 17-Jun-2025 08:25 are subject to review
Issued by Australian Energy Market Operator Ltd at 0820 hrs on 17 June 2025
PRICES ARE SUBJECT TO REVIEW for trading interval 17-Jun-2025 08:25.
AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs
This is an AEMO autogenerated Market Notice.
[EventId:202506170820_review] Prices for interval 17-Jun-2025 08:20 are subject to review
Issued by Australian Energy Market Operator Ltd at 0815 hrs on 17 June 2025
PRICES ARE SUBJECT TO REVIEW for trading interval 17-Jun-2025 08:20.
AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs
This is an AEMO autogenerated Market Notice.
[EventId:202506170815_review] Prices for interval 17-Jun-2025 08:15 are subject to review
Issued by Australian Energy Market Operator Ltd at 0810 hrs on 17 June 2025
PRICES ARE SUBJECT TO REVIEW for trading interval 17-Jun-2025 08:15.
AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs
This is an AEMO autogenerated Market Notice.
[EventId:202506170810_review] Prices for interval 17-Jun-2025 08:10 are subject to review
Issued by Australian Energy Market Operator Ltd at 0805 hrs on 17 June 2025
PRICES ARE SUBJECT TO REVIEW for trading interval 17-Jun-2025 08:10.
AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs
This is an AEMO autogenerated Market Notice.
[EventId:202506170805_review] Prices for interval 17-Jun-2025 08:05 are subject to review
Issued by Australian Energy Market Operator Ltd at 0800 hrs on 17 June 2025
PRICES ARE SUBJECT TO REVIEW for trading interval 17-Jun-2025 08:05.
AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs
This is an AEMO autogenerated Market Notice.
[EventId:202506170800_review] Prices for interval 17-Jun-2025 08:00 are subject to review
Issued by Australian Energy Market Operator Ltd at 0755 hrs on 17 June 2025
PRICES ARE SUBJECT TO REVIEW for trading interval 17-Jun-2025 08:00.
AEMO is reviewing these prices in accordance with:
- Clause 3.9.2B of the National Electricity Rules for Manifestly Incorrect Inputs
This is an AEMO autogenerated Market Notice.
Cancellation of a Non-Credible Contingency Event: Kamerunga - Barron Gorge 7184 132kV line and Kamerunga - Barron Gorge 7143 132kV line in QLD1 due to Lightning.
Cancellation of reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits is no longer reasonably possible. There is no longer any lightning activity in the vicinity of the following lines. Accordingly its classification has reverted to a non-credible contingency event.
Region: QLD1
Lines: Kamerunga - Barron Gorge 7184 132kV and Kamerunga - Barron Gorge 7143 132kV
Cancellation time: 17/06/2025 06:54
Constraint set(s) revoked:
NONE
Refer AEMO Electricity Market Notice 127609
Auto-generated on behalf of Manager NEM Real Time Operations
Reclassification of a Non-Credible Contingency Event: Kamerunga - Barron Gorge 7184 132kV line and Kamerunga - Barron Gorge 7143 132kV line in QLD1 due to Lightning.
Reclassification of a Non-Credible Contingency Event as a Credible Contingency Event due to Lightning. AEMO considers the simultaneous trip of the following circuits to now be more likely and reasonably possible. Accordingly AEMO has reclassified it as a credible contingency event.
Region: QLD1
Lines: Kamerunga - Barron Gorge 7184 132kV and Kamerunga - Barron Gorge 7143 132kV
Duration: 17/06/2025 04:52 until further notice
Constraint set(s) invoked:
NONE
Auto-generated on behalf of Manager NEM Real Time Operations