Inter-Regional Transfer limit variation - Murraylink control unavailable (SA Region)
Inter-Regional Transfer limit variation - Murraylink control unavailable (SA Region)
AEMO has been notified that the controls to vary Murraylink output are unavailable until further notice.
Constraint set I-CTRL_ISSUE_ML invoked from 1835 hrs.
The constraint set contains equations with the following interconnector on the LHS:
V-S-MNSP1
Manager NEM Real Time Operations
Inter-Regional Transfer limit variation - Directlink - NSW Region
Inter-Regional Transfer limit variation - Directlink - NSW Region
There has been an unplanned outage of all three Legs of Directlink .
The following constraint set was invoked at 1100 hrs 28/09/2023
N-X_MBTE_3
The constraint set contains the following interconnector on the left hand side.
N-Q-MNSP1
Refer AEMO Network Outage Scheduler (NOS) for further details.
Manager NEM Real Time Operations
Inter-regional transfer limit variation - Boambee South - Nambucca 9W7 132 kV Line - NSW region - 27/09/2023
Inter-regional transfer limit variation - Boambee South - Nambucca 9W7 132 kV Line - NSW region - 27/09/2023
At 1236 hrs 27/09/2023 there was an unplanned outage of the Boambee South - Nambucca 9W7 132 kV Line.
Constraint set(s) invoked: N-CHKS_ONE
This constraint set(s) contains equations with the following interconnectors on the LHS.
N-Q-MNSP1
NSW1-QLD1
Refer to the AEMO Network Outage Scheduler for further information.
Manager NEM Real Time Operations
Inter-regional transfer limit variation - Lismore132 7B1 132 kV CB - NSW region - 14/09/2023
Inter-regional transfer limit variation - Lismore132 7B1 132 kV CB - NSW region - 14/09/2023
At 0900 hrs 14/09/2023 there was a short notice outage of Lismore132 7B1 132 kV CB which offloads the Lismore132 Dunoon 9U6/L 132kV LINE.
The following constraint set(s) invoked at 0900 hrs 14/09/2023
N-LSDU_9U6
This constraint set(s) contains equations with the following interconnectors on the LHS.
N-Q-MNSP1
Refer to the AEMO Network Outage Scheduler for further information.
Manager NEM Real Time Operations
Cancellation Inter-Regional Transfer limit variation - Directlink control unavailable (NSW Region)
Cancellation Inter-Regional Transfer limit variation - Directlink control unavailable (NSW Region).
Refer AEMO Electricity Market Notice 109659
AEMO has been notified that the controls to vary Directlink output are now available.
Constraint set I-CTRL_ISSUE_TE revoked at 0215 hrs.
Manager NEM Real Time Operations
Inter-Regional Transfer limit variation - Directlink control unavailable (NSW Region)
Inter-Regional Transfer limit variation - Directlink control unavailable (NSW Region)
AEMO has been notified that the controls to vary Directlink output are unavailable until further notice.
Constraint set I-CTRL_ISSUE_TE invoked from 0130 hrs.
The constraint set contains equations with the following interconnector on the LHS:
N-Q-MNSP1
Manager NEM Real Time Operations
Inter-regional transfer limit variation - Heywood - Mortlake PS 500 kV Line - VIC region - 05/09/2023
Inter-regional transfer limit variation - Heywood - Mortlake PS 500 kV Line - VIC region - 05/09/2023
A planned outage of Heywood - Mortlake PS 500 kV Line in the VIC region was scheduled from 0800 hrs 05/09/2023 to 1700 hrs 05/09/2023.
The outage has been cancelled.
Refer to the AEMO Network Outage Scheduler for further information.
Manager NEM Real Time Operations
Inter-Regional Transfer limit variation - Murraylink
Inter-Regional Transfer limit variation - Murraylink
There has been an unplanned outage of the Murraylink interconnector.
The following constraint set was invoked at 0610 hrs 03/09/2023
I-MURAYLINK
The constraint set contains the following interconnectors on the left hand side.
V-S-MNSP1
VIC1-NSW1
Refer to AEMO Network Outage Scheduler (NOS) for further details.
Manager NEM Real Time Operations
Inter-regional transfer limit variation - LeFevre 6576 275 kV CB- SA region - 25/08/2023
Inter-regional transfer limit variation - LeFevre 6576 275 kV CB- SA region - 25/08/2023
At 1730 hrs 25/08/2023 there was a short notice outage of the LeFevre 6576 275 kV CB, de-loading the Pelican Point - Lefevre 275 kV line.
The following constraint set(s) invoked at 1730 hrs 25/08/2023:
S-LFPP_PELPT
This constraint set(s) contains equations with the following interconnectors on the LHS.
V-SA
Refer to the AEMO Network Outage Scheduler for further information.
Manager NEM Real Time Operations