Correction - Cancellation -Inter-regional transfer limit variation Victoria - South Australia (Heywood) interconnector - 01/03/17 - Market Notice type (Inter-Regional Transfer).
Correction - Cancellation -Inter-regional transfer limit variation Victoria - South Australia (Heywood) interconnector - 01/03/17 - Market Notice type (Inter-Regional Transfer).
Refer AEMO Electricity Market Notice 57778
The upper limit of 500 MW placed on the Victoria - South Australia (Heywood) interconnector has been removed.
The following constraint was invoked from 1810 hrs to 1835 hrs
I-VS_500
The constraint contains the following interconnector on the LHS
V-SA
Manager NEM Real Time Operations
Inter regional transfer limit variation Victoria - South Australia (Heywood) interconnector- 01/03/17
Inter regional transfer limit variation Victoria - South Australia (Heywood) interconnector - 01/03/17
To manage power system security an upper limit of 500 MW has been placed on the Victoria - South Australia (Heywood) interconnector
The following constraint is invoked from 1810 hrs to 1930 hrs
I-VS_500
The constraint contains the following interconnector on the LHS
V-SA
Manager NEM Real Time Operations
Inter-Regional Transfer limit variation - Brinkworth - Templers West 275 kV transmission line outage South Australia
Inter-Regional Transfer limit variation - Brinkworth - Templers West 275 kV transmission line outage South Australia
There is a short notice outage of the Brinkworth - Templers West 275 kV transmission line in South Australia
Constraint set S-BRTW has been invoked from 1125 hrs
This Constraint Set contains equations with the following interconnector on the LHS.
V-MNSP1
See Network Outage Scheduler (NOS) for further details
Manager NEM Realtime Operations
Inter-Regional Transfer Limit Variation New South Wales Region Monday, 27 February 2017 Directlink
Inter-Regional Transfer Limit Variation New South Wales Region Monday, 27 February 2017 Directlink
An unplanned outage of the No 2 Leg of Directlink has occurred at 0719 hrs
The following constraint set is invoked for this outage from 0725 hrs
N-MBTE_1
The outage constraint set contains the following interconnector on the left hand side.
N-Q-MNSP1
See AEMO Network Outage Scheduler (NOS) for details.
Manager NEM Real Time Operations
Cancelation- Inter-Regional Transfer limit variation - Victoria Region - Monday, 27 February 2017
Cancelation- Inter-Regional Transfer limit variation - Victoria Region - Monday, 27 February 2017
Refer AEMO Electricity Market Notice 57709
The APD - Heywood - Mortlake No.2 500 kV Transmission line in the Victoria region returned to service at 0609 hrs.
The following constraint sets have been revoked;
F-V-HYMO
S-X_BC_CP
V-HYMO
The constraint has the following interconnectors on the left hand side.
V-S-MNSP1
VIC1-NSW1
T-V-MNSP1
V-SA
Manager NEM Real Time Operations
Inter-Regional Transfer limit variation - Vic Region - 27 Feb 2017
Inter-Regional Transfer limit variation - Vic Region - 27 Feb 2017
An unplanned outage of the APD - Heywood - Mortlake No.2 500 kV Line in the Victoria region occured at 0445 hrs.
The following constraint sets have been invoked;
F-V-HYMO
S-X_BC_CP
V-HYMO
The constraint has the following interconnectors on the left hand side.
V-S-MNSP1
VIC1-NSW1
T-V-MNSP1
V-SA
Manager NEM Realtime Operations
Cancellation -Inter-regional transfer limit variation: Hazelwood - South Morang No.1 500kV Line (VIC) - Voltage Control - Sunday, 26 February 2017
Cancellation -Inter-regional transfer limit variation: Hazelwood - South Morang No.1 500kV Line (VIC) - Voltage Control - Sunday, 26 February 2017
Refer AEMO Electricity Market Notice 57691
The Hazelwood - South Morang No.1 500kV Line has been returned to service.
The following constraint set was revoked at 0920 hrs
V-X_HWSM_SMF2_STAB
The constraint set contains equations with the following interconnectors on the LHS.
T-V-MNSP1
V-S-MNSP1
V-SA
VIC1-NSW1
Manager NEM Real Time Operations
Inter-regional transfer limit variation: Hazelwood - South Morang No.1 500kV Line (VIC) - Voltage Control - 26/02/17
Inter-regional transfer limit variation: Hazelwood - South Morang No.1 500kV Line (VIC) - Voltage Control - 26/02/17
The Hazelwood - South Morang No.1 500kV Line has been de-energised to manage voltages in the VIC region.
The following constraint set was invoked at 0115 hrs
V-X_HWSM_SMF2_STAB
The constraint set contains equations with the following interconnectors on the LHS.
T-V-MNSP1
V-S-MNSP1
V-SA
VIC1-NSW1
Refer to AEMO Network Outage Schedule for further details and return to service times.
Manager NEM Real Time Operations
Inter-regional transfer limit variation: Dapto - Sydney South No. 11 330 kV line - NSW region - 23/02/17
Inter-regional transfer limit variation: Dapto - Sydney South No. 11 330 kV line - NSW region - 23/02/17
The planned outage of the Dapto - Sydney South No. 11 (NSW region) has returned to service early.
The following constraint set was revoked at 08:15 hrs
N-DTSS_11
The constraint set contains equations the following interconnectors on the LHS
N-Q-MNSP1
NSW1-QLD1
VIC1-NSW1
Refer to AEMO Network Outage Scheduler (NOS) for further details.
Manager NEM Real Time Operations