Inter-regional transfer limit variation - Directlnk DC2 80kV LINE- NSW region - 22/12/2025
Inter-regional transfer limit variation - Directlnk DC2 80kV LINE- NSW region - 22/12/2025
A planned outage of Directlnk DC2 80kV LINE in the NSW region was scheduled from 1520 hrs 21/12/2025 to 1700 hrs 22/12/2025.
The outage has been completed and Directlnk DC2 80kV LINE returned to service at 0910 hrs 22/12/2025
Constraint set(s) revoked: N-X_MBTE_1
Manager NEM Real Time Operations
Inter-regional transfer limit variation - Kemps Creek 500/330 kV #3 Transformer - NSW region - 20/12/2025
Inter-regional transfer limit variation - Kemps Creek 500/330 kV #3 Transformer - NSW region - 20/12/2025
At 2104 hrs 20/12/2025 there was an unplanned outage of Kemps Creek 500/330 kV #3 Transformer.
The following constraint set(s) invoked at 2115 hrs 20/12/2025
N-KC_TX
This constraint set(s) contains equations with the following interconnectors on the LHS.
N-Q-MNSP1,NSW1-QLD1,VIC1-NSW1
Refer to the AEMO Network Outage Scheduler for further information.
Manager NEM Real Time Operations
Inter-regional transfer limit variation - Halys-Braemar 8814 275kV LINE - QLD region - 18/12/2025
Inter-regional transfer limit variation - Halys-Braemar 8814 275kV LINE - QLD region - 18/12/2025
At 0759 hrs 18/12/2025 there was an unplanned outage of Halys-Braemar 8814 275kV LINE.
The following constraint set invoked at 0805 hrs 18/12/2025
Q-BRHA
This constraint set contains equations with the following interconnectors on the LHS.
NSW1-QLD1
Refer to the AEMO Network Outage Scheduler for further information.
Manager NEM Real Time Operations
Inter-regional transfer limit variation - Tamworth 1 330kV SVC - NSW region - 16/12/2025
Inter-regional transfer limit variation - Tamworth 1 330kV SVC - NSW region - 16/12/2025
At 1642 hrs 16/12/2025 there was an unplanned outage of Tamworth 1 330kV SVC.
The following constraint set invoked at 1650 hrs 16/12/2025
N-TW_SVC
This constraint set contains equations with the following interconnectors on the LHS.
N-Q-MNSP1,NSW1-QLD1
Refer to the AEMO Network Outage Scheduler for further information.
Manager NEM Real Time Operations
Inter-regional transfer limit variation - Dapto - Sydney South (11) 330kV line- NSW region - 16/12/2025
Inter-regional transfer limit variation - Dapto - Sydney South (11) 330kV line- NSW region - 16/12/2025
A planned outage of Dapto - Sydney South (11) 330kV line in the NSW region was scheduled from 0630 hrs 16/12/2025 to 1500 hrs 17/12/2025.
The outage has been completed and Dapto - Sydney South (11) 330kV line returned to service at 1352 hrs 16/12/2025
Constraint set(s) revoked: N-DTSS_11
Manager NEM Real Time Operations
Inter-regional transfer limit variation - Woolooga No. 4 275 kV SVC - QLD region - 16/12/2025
Inter-regional transfer limit variation - Woolooga No. 4 275 kV SVC - QLD region - 16/12/2025
At 1032 hrs 16/12/2025 there was an unplanned outage of Woolooga No. 4 275 kV SVC.
The following constraint set(s) invoked at 1040 hrs 16/12/2025
Q-WO_VC
This constraint set(s) contains equations with the following interconnectors on the LHS.
N-Q-MNSP1,NSW1-QLD1
Refer to the AEMO Network Outage Scheduler for further information.
Manager NEM Real Time Operations
Inter-regional transfer limit variation - Yass - Marulan 5 330kV line - NSW region - 10/12/2025
Inter-regional transfer limit variation - Yass - Marulan 5 330kV line - NSW region - 10/12/2025
At 1616 hrs 10/12/2025 there was an unplanned outage of Yass - Marulan 5 330kV line.
The following constraint set invoked at 1625 hrs 10/12/2025
N-MNYS_5_WG_CLOSE
This constraint set contains equations with the following interconnectors on the LHS.
VIC1-NSW1, V-S-MNSP1
Refer to the AEMO Network Outage Scheduler for further information.
Manager NEM Real Time Operations
Inter-regional transfer limit variation - Tamworth No. 1 330kV SVC - NSW region - 10/12/2025
Inter-regional transfer limit variation - Tamworth No. 1 330kV SVC - NSW region - 10/12/2025
At 1356 hrs 10/12/2025 there was an unplanned outage of Tamworth No. 1 330kV SVC.
The following constraint sets invoked at 1410 hrs 10/12/2025
N-TW_SVC
The constraint sets contains equations with the following interconnectors on the LHS.
N-Q-MNSP1,NSW1-QLD1
Refer to the AEMO Network Outage Scheduler for further information.
Manager NEM Real Time Operations
Inter-regional transfer limit variation - Armidale to Sapphire 8E 330kV Line - NSW region - 10/12/2025
Inter-regional transfer limit variation - Armidale to Sapphire 8E 330kV Line- NSW region - 10/12/2025
A planned outage of Armidale to Sapphire 8E 330kV Line in the NSW region was scheduled from 0600 hrs 10/12/2025 to 1500 hrs 10/12/2025.
The outage has been completed and Armidale to Sapphire 8E 330kV Line returned to service at 1210 hrs 10/12/2025
Constraint sets revoked: N-ARSR_8E, N-DM_SVC
Manager NEM Real Time Operations