Inter-regional transfer limit variation -Kerang SVC - VIC region - 10/01/2026
Inter-regional transfer limit variation - Kerang SVC - VIC region - 10/01/2026
At 0825 hrs 10/01/2026 there was an unplanned outage of Kerang SVC .
The following constraint set(s) invoked at 0830 hrs 10/01/2026
V-KGTS_SVC
This constraint set(s) contains equations with the following interconnectors on the LHS.
V-S-MNSP1
Refer to the AEMO Network Outage Scheduler for further information.
Manager NEM Real Time Operations
Inter-regional transfer limit variation - constraint automation to manage Power System Security in VIC region - 10/01/2026
In order to maintain the power system in a secure operating state in the VIC region, AEMO has invoked automated constraint set CA_BRIS_5873DCEF from 0500 hrs until further notice.
This constraint set contains equations with the following interconnector on the LHS;
V-S-MNSP1
VIC1-NSW1
VIC-SA
Manager NEM Real Time Operations
Cancellation- Inter-regional transfer limit variation - constraint automation to manage Power System Security in VIC region - 09/01/2026
Cancellation- Inter-regional transfer limit variation - constraint automation to manage Power System Security in VIC region - 09/01/2026
Refer market notice: 132616
In order to maintain the power system in a secure operating state in the VIC region, AEMO has invoked automated constraint set CA_BRIS_58730C07 from 1410 hrs until further notice.
This constraint set contains equations with the following interconnector on the LHS;
V-S-MNSP1
VIC1-NSW1
Manager NEM Real Time Operations
Inter-regional transfer limit variation - Dederang - South Morang No2 330kV line - VIC region - 09/01/2026
Inter-regional transfer limit variation - Dederang - South Morang No2 330kV line - VIC region - 09/01/2026
At 1700 hrs 09/01/2026 there was an unplanned outage of Dederang - South Morang No2 330kV line.
The following constraint set(s) invoked at 1720 hrs 09/01/2026
V-DBUSS_T
This constraint set(s) contains equations with the following interconnectors on the LHS.
VIC1-NSW1
Refer to the AEMO Network Outage Scheduler for further information.
Manager NEM Real Time Operations
Inter-regional transfer limit variation - Dederang - Murray No 67 330kV line - VIC region - 09/01/2026
Inter-regional transfer limit variation - Dederang - Murray No 67 330kV line - VIC region - 09/01/2026
At 1603 hrs 09/01/2026 there was an unplanned outage of Dederang - Murray No 67 330kV line.
The following constraint set(s) invoked at 1610 hrs 09/01/2026
V-DDMS
V-DBUSS_L
This constraint set(s) contains equations with the following interconnectors on the LHS.
VIC1-NSW1,NSW1-QLD1,V-S-MNSP1
Refer to the AEMO Network Outage Scheduler for further information.
Manager NEM Real Time Operations
Inter-regional transfer limit variation - constraint automation to manage Power System Security in VIC region - 09/01/2026
In order to maintain the power system in a secure operating state in the VIC region, AEMO has invoked automated constraint set CA_BRIS_58730C07 from 1410 hrs until further notice.
This constraint set contains equations with the following interconnector on the LHS;
V-S-MNSP1
VIC1-NSW1
Manager NEM Real Time Operations
Inter-regional transfer limit variation - Mt England Tarong (8812) 275kV Line - QLD region - 08/01/2026
Inter-regional transfer limit variation - Mt England Tarong (8812) 275kV Line - QLD region - 08/01/2026
At 0240 hrs 08/01/2026 there was a short notice outage of Mt England Tarong (8812) 275kV Line.
The following constraint set(s) invoked at 0240 hrs 08/01/2026
Q-TRME
This constraint set(s) contains equations with the following interconnectors on the LHS.
N-Q-MNSP1,NSW1-QLD1
Refer to the AEMO Network Outage Scheduler for further information.
Manager NEM Real Time Operations
Inter-regional transfer limit variation - Liverpool - Sydney South No. 12 330 kV Line - NSW region - 24/12/2025
Inter-regional transfer limit variation - Liverpool - Sydney South No. 12 330 kV Line - NSW region - 24/12/2025
At 1314 hrs 24/12/2025 there was a short notice outage of Liverpool - Sydney South No. 12 330 kV Line.
The following constraint set(s) invoked at 1315 hrs 24/12/2025
N-LPSS_12
This constraint set(s) contains equations with the following interconnectors on the LHS.
VIC1-NSW1,N-Q-MNSP1,NSW1-QLD1
Refer to the AEMO Network Outage Scheduler for further information.
Manager NEM Real Time Operations
Inter-regional transfer limit variation - [outage element] - NSW region - 23/12/2025
Inter-regional transfer limit variation - [outage element] - NSW region - 23/12/2025
A planned outage of Tamworth 1 330kV SVC in the NSW region was scheduled from 0640 hrs 16/12/2025 to 1640 hrs 31/12/2025.
The outage has been completed and Tamworth 1 330kV SVC returned to service at 0845 hrs 23/12/2025
Constraint set(s) revoked: N-TW_SVC
Manager NEM Real Time Operations