Inter-regional transfer limit variation - Waterloo - Mintaro line 132 kV - SA region - 06/03/2026
Inter-regional transfer limit variation - Waterloo - Mintaro line 132 kV - SA region - 06/03/2026
At 1445 hrs 06/03/2026 there was a short notice outage of Waterloo - Mintaro line 132 kV.
The following constraint set(s) invoked at 1445 hrs 06/03/2026
S-X_MNWT+BRMN+CB
This constraint set(s) contains equations with the following interconnectors on the LHS.
V-S-MNSP1,V-SA
Refer to the AEMO Network Outage Scheduler for further information.
Manager NEM Real Time Operations
Cancellation -Inter-Regional Transfer limit variation - Manage Power System Security in NSW Region - 05/03/2026
Cancellation - Inter-Regional Transfer limit variation - Manage Power System Security in NSW Region - 05/03/2026
Refer market notice 134558
In order to maintain the power system in a secure operating state in the New South Wales region, AEMO has invoked a discretionary constraint to limit the transfer from Qld to NSW.
.
Constraint set I-QN_550 was invoked from 1320 hrs until 1710 hrs
This Constraint Set contains equations with the following interconnector on the LHS;
NSW1 - QLD1
Manager NEM Real Time Operations
Inter-Regional Transfer limit variation - Manage Power System Security in NSW Region - 05/03/2026
Inter-Regional Transfer limit variation - Manage Power System Security in NSW Region - 05/03/2026
In order to maintain the power system in a secure operating state in the New South Wales region, AEMO has invoked a discretionary constraint to limit the transfer from Qld to NSW.
.
Constraint set I-QN_550 has been invoked from 1320 hrs until further advice
This Constraint Set contains equations with the following interconnector on the LHS;
NSW1 - QLD1
Manager NEM Real Time Operations
Inter-regional transfer limit variation - Stockdill Upper Tumut No1 330kV line - NSW region - 04/03/2026
Inter-regional transfer limit variation - Stockdill Upper Tumut No1 330kV line - NSW region - 04/03/2026
At 0843 hrs 04/03/2026 there was an unplanned outage of Stockdill Upper Tumut No1 330kV line.
The following constraint set(s) invoked at 0855 hrs 04/03/2026
N-SDUT_1
This constraint set(s) contains equations with the following interconnectors on the LHS.
VIC1-NSW1,V-S-MNSP1
Refer to the AEMO Network Outage Scheduler for further information.
Manager NEM Real Time Operations
Inter-regional transfer limit variation - Dumaresq SVC, Tamworth SVC and Taree to Port Macquarie 964 132 kV line - NSW region - 03/03/2026
Inter-regional transfer limit variation - Dumaresq SVC, Tamworth SVC and Taree to Port Macquarie 964 132 kV line - NSW region - 03/03/2026
At 1910 hrs 03/03/2026 there was a short notice outage of Dumaresq SVC, Tamworth SVC and Taree to Port Macquarie 964 132 kV line.
The following constraint set(s) invoked at 1910 hrs 03/03/2026
N-TAPM_964, N-X_DM+TW_SVC
This constraint set(s) contains equations with the following interconnectors on the LHS.
N-Q-MNSP1,NSW1-QLD1
Refer to the AEMO Network Outage Scheduler for further information.
Manager NEM Real Time Operations
Inter-regional transfer limit variation - Greenbank 275 kV SVC - QLD region - 02/03/2026
Inter-regional transfer limit variation - Greenbank 275 kV SVC - QLD region - 02/03/2026
At 1200 hrs 02/03/2026 there was a short notice outage of Greenbank 275 kV SVC.
The following constraint set(s) invoked at 1200 hrs 02/03/2026
Q-GB_VC
This constraint set(s) contains equations with the following interconnectors on the LHS.
NSW1-QLD1,N-Q-MNSP1
Refer to the AEMO Network Outage Scheduler for further information.
Manager NEM Real Time Operations
Inter-regional transfer limit variation - Black Range No.2 275 kV Series Capacitor - SA region - 27/02/2026
Inter-regional transfer limit variation - Black Range No.2 275 kV Series Capacitor - SA region - 27/02/2026
At 1840 hrs 27/02/2026 there was an unplanned outage of of Black Range No.2 275 kV Series Capacitor.
The following constraint set invoked at 1850 hrs 27/02/2026
S-BC_CP
This constraint set(s) contains equations with the following interconnectors on the LHS.
V-SA,V-S-MNSP1
Refer to the AEMO Network Outage Scheduler for further information.
Manager NEM Real Time Operations
Inter-regional transfer limit variation - Directlk_Q Terranora 9901 110kV LINE - NSW region - 12/02/2026
Inter-regional transfer limit variation - Directlk_Q Terranora 9901 110kV LINE - NSW region - 12/02/2026
At 1030 hrs 12/02/2026 there was a short notice outage of Directlk_Q Terranora 9901 110kV LINE.
The following constraint set(s) invoked at 1230 hrs 12/02/2026
N-X_MBTE_3
This constraint set(s) contains equations with the following interconnectors on the LHS.
N-Q-MNSP1
Refer to the AEMO Network Outage Scheduler for further information.
Manager NEM Real Time Operations
Inter-regional transfer limit variation - Mudgeeraba No 5 275/110kV transformer - QLD region - 09/02/2026
Inter-regional transfer limit variation -Mudgeeraba No 5 275/110kV transformer - QLD region - 09/02/2026
At 0801 hrs 09/02/2026 there was an unplanned outage of Mudgeeraba No 5 275/110kV transformer.
The following constraint set(s) invoked at 0805 hrs 09/02/2026
Q-MUTX
This constraint set(s) contains equations with the following interconnectors on the LHS.
N-Q-MNSP1
Refer to the AEMO Network Outage Scheduler for further information.
Manager NEM Real Time Operations