Market Notices

144136MARKET INTERVENTION24/05/2026 04:16:17 AM

Direction - SA region 24/05/2026

AEMO ELECTRICITY MARKET NOTICE

Direction - SA region 24/05/2026

In accordance with section 116 of the National Electricity Law, AEMO has issued a direction to a participant in the SA region. For the purposes of the National Electricity Rules this is a direction under clause 4.8.9(a1)(1).

The issue of the direction commences an AEMO intervention event. AEMO declares all trading intervals during the event to be intervention trading intervals, commencing from the interval ending 0405 hrs on 24/05/2026.

Intervention pricing does not apply to this AEMO intervention event.

AEMO may issue or revoke additional directions in order to meet the current requirement, unless sufficient market response is provided. A further market notice will be issued when all directions related to this requirement have been cancelled.


Manager NEM Real Time Operations
     
144135MARKET INTERVENTION24/05/2026 04:15:55 AM

Direction - in SA region to AGL SA Generation Pty Limited - Barker Inlet Power Station

AEMO ELECTRICITY MARKET NOTICE

Direction - in SA region to AGL SA Generation Pty Limited - Barker Inlet Power Station


In accordance with section 116 of the National Electricity Law, AEMO is issuing a direction to AGL SA Generation Pty Limited. For the purposes of the National Electricity Rules this is a direction under clause 4.8.9(a1)(1).

Direction issued to: AGL SA Generation Pty Limited - Barker Inlet Power Station at 0400 hrs 24/05/2026
Type of resource: generating unit
Required actions: Synchronise and follow dispatch targets at 0405 hrs 24/05/2026
Services provided: Voltage Control
Circumstances necessitating the Direction:Voltage
Circumstances necessitating the Direction additional detail: The synchronous generating units currently expected to be synchronised in SA will be inadequate to maintain sufficient Voltage Control in SA. Intervention is required to maintain the power system in a secure operating state.
Expected duration: Until further notice.

AGL SA Generation Pty Limited does not incur any civil monetary liability for a relevant action taken in accordance with this direction unless the action is taken in bad faith.

Manager NEM Real Time Operations
     
144134MARKET INTERVENTION23/05/2026 02:32:17 PM

Cancellation - Direction - Qld region - 23/05/2026

AEMO ELECTRICITY PARTICIPANT NOTICE

Cancellation - Direction - Qld region - 23/05/2026

Refer to Market Notice 144132

The requirement for AEMO to issue a direction to maintain the power system in a secure operating state has ended. All associated directions are cancelled from 1430 hrs on 23/05/2026.

Manager NEM Real Time Operations
     
144132MARKET INTERVENTION23/05/2026 12:48:56 PM

Direction - Qld region 23/05/2026

AEMO ELECTRICITY MARKET NOTICE.

Direction - Qld region 23/05/2026

In accordance with section 116 of the National Electricity Law, AEMO has issued a direction to a participant in the Qld region.

The direction was necessary to maintain the power system in a secure operating state.

AEMO may issue or revoke additional directions in order to meet the current requirement, unless sufficient market response is provided.

A further market notice will be issued when all directions related to this requirement have been cancelled.

For the purposes of the National Electricity Rules this was a clause 4.8.9 instruction under clause 4.8.9(a).


Manager NEM Real Time Operations
     
144122INTER-REGIONAL TRANSFER20/05/2026 07:18:48 PM

Inter-regional transfer limit variation - South Morang F2 500/330kV XFMR - VIC region - 20/05/2026

AEMO ELECTRICITY MARKET NOTICE

Inter-regional transfer limit variation - South Morang F2 500/330kV XFMR - VIC region - 20/05/2026

The outage has been rescheduled for 0630 hrs 18/05/2026 to 1700 hrs 22/05/2026.

Constraint set(s) invoked: V-SMTX_F_R

This constraint set(s) contains equations with the following interconnectors on the LHS.
T-V-MNSP1,V-SA,VIC1-NSW1,V-S-MNSP1

Refer to the AEMO Network Outage Scheduler for further information.

Manager NEM Real Time Operations
     
144104INTER-REGIONAL TRANSFER17/05/2026 01:02:38 PM

Inter-Regional Transfer limit variation - Murraylink

AEMO ELECTRICITY MARKET NOTICE

Inter-Regional Transfer limit variation - Murraylink

There has been an unplanned outage of Murraylink.

The following constraint set was invoked at 1300 hrs 17/05/2026

I-ML_ZERO

The constraint set contains the following interconnector on the left hand side.

V-S-MNSP1

Refer to AEMO Network Outage Scheduler (NOS) for further details.

Manager NEM Real Time Operations
     
144100INTER-REGIONAL TRANSFER17/05/2026 01:48:30 AM

Inter-Regional Transfer limit variation - Murraylink

AEMO ELECTRICITY MARKET NOTICE

Inter-Regional Transfer limit variation - Murraylink

There has been an unplanned outage of Murraylink.

The following constraint set was invoked at 0145 hrs 17/05/2026

I-ML_ZERO

The constraint set contains the following interconnector on the left hand side.

V-S-MNSP1

Refer to AEMO Network Outage Scheduler (NOS) for further details.

Manager NEM Real Time Operations
     
144097INTER-REGIONAL TRANSFER16/05/2026 08:49:36 PM

Inter-regional transfer limit variation - Murraylink Redcliffs Convertor station - VIC region - 16/05/2026

AEMO ELECTRICITY MARKET NOTICE

Inter-regional transfer limit variation - Murraylink Redcliffs Convertor station - VIC region - 16/05/2026

At 2045 hrs 16/05/2026 there was a short notice outage of Murraylink Redcliffs Convertor station.

The following constraint set(s) invoked at 2045 hrs 16/05/2026
I-MURRAYLINK

This constraint set(s) contains equations with the following interconnectors on the LHS.
VIC1-NSW1,V-S-MNSP1

Refer to the AEMO Network Outage Scheduler for further information.

Manager NEM Real Time Operations
     
144094INTER-REGIONAL TRANSFER16/05/2026 07:20:55 PM

Inter-Regional Transfer limit variation - Murraylink

AEMO ELECTRICITY MARKET NOTICE

Inter-Regional Transfer limit variation - Murraylink

There has been an unplanned outage of Murraylink.

The following constraint set was invoked at 1915 hrs 16/05/2026

I-ML_ZERO

The constraint set contains the following interconnector on the left hand side.

V-S-MNSP1

Refer to AEMO Network Outage Scheduler (NOS) for further details.

Manager NEM Real Time Operations
     