Market Notices

58720INTER-REGIONAL TRANSFER13/06/2017 08:02:37 AM

Cancellation of Planned outage of Heywood - APD No. 1 500kV line in Victoria region 13/06/2017

AEMO ELECTRICITY MARKET NOTICE.

The planned outage of Heywood - APD No. 1 500kV line in Victoria region from 0800 hrs to 1500 hrs 13/06/17 has been withdrawn by the participant.

Constraint Set V-APHY_1 has been revoked.

The constraint set contains equations with the following interconnector on the LHS
V-SA

Refer AEMO Network Outage Schedule (NOS) for further details.

Manager NEM Real Time Operations
58719INTER-REGIONAL TRANSFER12/06/2017 06:14:51 AM

Cancellation -Inter-regional transfer limit variation: Hazelwood - South Morang No.2 500kV Line (VIC) - Voltage Control - 12 June 2017

AEMO ELECTRICITY MARKET NOTICE

Cancellation -Inter-regional transfer limit variation: Hazelwood - South Morang No.2 500kV Line (VIC) - Voltage Control - 12 June 2017

Refer AEMO Electricity Market Notice 58718

The Hazelwood - South Morang No 2 500kV Line has been returned to service.

The following constraint set was revoked at 0615 hrs

V-HWSM

The constraint set contains equations with the following interconnectors on the LHS.
T-V-MNSP1
V-S-MNSP1
V-SA
VIC1-NSW1

Manager NEM Real Time Operations
58718INTER-REGIONAL TRANSFER12/06/2017 02:38:45 AM

Inter-regional transfer limit variation: Hazelwood - South Morang No.2 500kV Line (VIC) - Voltage Control - 12 June 2017

AEMO ELECTRICITY MARKET NOTICE

Inter-regional transfer limit variation: Hazelwood - South Morang No.2 500kV Line (VIC) - Voltage Control - 12 June 2017

The Hazelwood - South Morang No.2 500kV Line has been de-energised to manage voltages in the VIC region.

The following constraint set was invoked at 0235 hrs
V-HWSM

The constraint set contains equations with the following interconnectors on the LHS.
T-V-MNSP1
V-S-MNSP1
V-SA
VIC1-NSW1

Refer to AEMO Network Outage Schedule for further details.

Manager NEM Real Time Operations
58715INTER-REGIONAL TRANSFER11/06/2017 06:22:27 AM

Inter regional transfer limit variation - Glen Innes to Tenterfield (96R) 132kV transmission line (NSW) - 11 Jun 2017

AEMO ELECTRICITY MARKET NOTICE

Inter regional transfer limit variation - Glen Innes to Tenterfield (96R) 132kV transmission line (NSW) - 11 Jun 2017

At 0544 hrs Glen Innes to Tenterfield (96R) 132kV Line opened automatically at Glen Innes end.

The following constraint set was invoked

N-GITN_96R
N-X_96H-96R

The constraint set contains equations with the following interconnectors on the LHS.

N-Q-MNSP1

Refer to NOS for further details

Manager NEM Realtime Operations
58706INTER-REGIONAL TRANSFER09/06/2017 12:00:10 PM

Inter-Regional Transfer Limit Variation New South Wales Region, 09/06/2017 Directlink

AEMO ELECTRICITY MARKET NOTICE

Inter-Regional Transfer Limit Variation New South Wales Region, 09/06/2017 Directlink

An unplanned outage of the No 2 Leg of Directlink has occurred at 1147 hrs

See AEMO Network Outage Scheduler (NOS) for details.

The following constraint set is invoked for this outage from 1155 hrs

N-MBTE_1

The outage constraint set contains the following interconnector on the left hand side.

N-Q-MNSP1


Manager NEM Real Time Operations
58692INTER-REGIONAL TRANSFER04/06/2017 07:43:47 PM

Cancellation Inter-regional transfer limit variation : Murraylink

AEMO ELECTRICITY MARKET NOTICE

Cancellation Inter-regional transfer limit variation : Murraylink

Refer Electricity Market Notice 58691

A transmission outage at Ballarat has been returned to service.
The following constraint set was revoked at 1935 hrs 04/06/2017.
I-VSML_-100

This Constraint Set contains an equation with the following interconnector on the LHS.
V-S-MNSP1

See the Network Outage schedule for further information

Manager NEM Real Time Operations

58691INTER-REGIONAL TRANSFER04/06/2017 05:15:21 PM

Inter-regional transfer limit variation : Murraylink

AEMO ELECTRICITY MARKET NOTICE

Inter-regional transfer limit variation : Murraylink

To manage power system security in the Victoria region the following constraint set was invoked at 1710 hrs until transmission outages at Ballarat are returned to service.
I-VSML_-050

This Constraint Set contains an equation with the following interconnector on the LHS.
V-S-MNSP1

Further adjustments may be required
See the Network Outage schedule for further information

Manager NEM Real Time Operations
58685INTER-REGIONAL TRANSFER03/06/2017 08:45:02 PM

Inter-Regional Transfer Limit Variation New South Wales Region Saturday, 03/06/2017

AEMO ELECTRICITY MARKET NOTICE

Refer market notice 58684

Inter-Regional Transfer Limit Variation New South Wales Region Saturday, 03/06/2017



The Sydney North - Vales Point 22 330 kV line open at Vales Point due Vales Point GEN 330 kV busbar trip at 2010 hrs

The following constraint set was invoked for this outage from 2025 hrs to 2035 hrs

N-SNVP_22

The outage constraint set contains the following interconnector on the left hand side.

N-Q-MNSP1
NSW1-QLD1
VIC1-NSW1

Manager NEM Real Time Operations
58683INTER-REGIONAL TRANSFER03/06/2017 05:33:59 PM

Inter-regional transfer limit variation : Murraylink

AEMO ELECTRICITY MARKET NOTICE

Inter-regional transfer limit variation : Murraylink
To manage power system security in the Victoria region the following constraint set was invoked at 1730 hrs until transmission outages at Ballarat are returned to service.
I-VSML_-40
This Constraint Set contains an equation with the following interconnector on the LHS.
V-S-MNSP1

Further adjustments may be required
See the Network Outage schedule for further information

Manager NEM Real Time Operations