109547INTER-REGIONAL TRANSFER03/09/2023 06:12:47 AM

Inter-Regional Transfer limit variation - Murraylink

AEMO ELECTRICITY MARKET NOTICE

Inter-Regional Transfer limit variation - Murraylink

There has been an unplanned outage of the Murraylink interconnector.

The following constraint set was invoked at 0610 hrs 03/09/2023

I-MURAYLINK

The constraint set contains the following interconnectors on the left hand side.

V-S-MNSP1
VIC1-NSW1

Refer to AEMO Network Outage Scheduler (NOS) for further details.

Manager NEM Real Time Operations
109447INTER-REGIONAL TRANSFER25/08/2023 05:32:12 PM

Inter-regional transfer limit variation - LeFevre 6576 275 kV CB- SA region - 25/08/2023

AEMO ELECTRICITY MARKET NOTICE

Inter-regional transfer limit variation - LeFevre 6576 275 kV CB- SA region - 25/08/2023

At 1730 hrs 25/08/2023 there was a short notice outage of the LeFevre 6576 275 kV CB, de-loading the Pelican Point - Lefevre 275 kV line.

The following constraint set(s) invoked at 1730 hrs 25/08/2023:
S-LFPP_PELPT


This constraint set(s) contains equations with the following interconnectors on the LHS.
V-SA

Refer to the AEMO Network Outage Scheduler for further information.

Manager NEM Real Time Operations
109441INTER-REGIONAL TRANSFER25/08/2023 01:03:02 PM

Inter-Regional Transfer limit variation - Directlink - NSW Region

AEMO ELECTRICITY MARKET NOTICE

Inter-Regional Transfer limit variation - Directlink - NSW Region

There has been an unplanned outage of all three Legs of Directlink .

The following constraint set was invoked at 1240 hrs 25/08/2023

N-X_MBTE_3

The constraint set contains the following interconnector on the left hand side.

N-Q-MNSP1

Refer AEMO Network Outage Scheduler (NOS) for further details.

Manager NEM Real Time Operations
109440INTER-REGIONAL TRANSFER25/08/2023 08:26:57 AM

Inter-Regional Transfer limit variation - Directlink - NSW Region

AEMO ELECTRICITY MARKET NOTICE

Inter-Regional Transfer limit variation - Directlink - NSW Region

There has been an unplanned outage of the No.2 and No.3 Legs of Directlink .

The following constraint set was invoked at 0825 hrs 25/08/2023

N-X_MBTE_3

The constraint set contains the following interconnector on the left hand side.

N-Q-MNSP1

Refer AEMO Network Outage Scheduler (NOS) for further details.

Manager NEM Real Time Operations
109384INTER-REGIONAL TRANSFER19/08/2023 04:00:35 AM

Inter-regional transfer limit variation: Middle Ridge - Greenbank No 8848 275 kV Line (Qld) - Voltage Control

AEMO ELECTRICITY MARKET NOTICE

Inter-regional transfer limit variation: Middle Ridge - Greenbank No 8848 275 kV Line (Qld) - Voltage Control

Middle Ridge - Greenbank No 8848 275 kV Line has been de-energised to manage voltages in the Queensland region.

The following constraint set was invoked at 0400 hrs 19/08/2023

Q-MRGB_8848_8849

The constraint set contains equations with the following interconnectors on the LHS.

N-Q-MNSP1
NSW1-QLD1

Refer to AEMO Network Outage Scheduler (NOS) for further details

Manager NEM Real Time Operations
109383INTER-REGIONAL TRANSFER18/08/2023 06:42:03 PM

Inter-regional transfer limit variation - Tamworth SVC - NSW region - 18/08/2023

AEMO ELECTRICITY MARKET NOTICE

Inter-regional transfer limit variation - Tamworth SVC - NSW region - 18/08/2023

At 1820 hrs 18/08/2023 there was a short notice outage of the Tamworth SVC.

The following constraint set(s) invoked at 1820 hrs 18/08/2023
N-TW_SVC and N-X_LS+TW_SVC

This constraint set(s) contains equations with the following interconnectors on the LHS.
N-Q-MNSP1,NSW1-QLD1

Refer to the AEMO Network Outage Scheduler for further information.

Manager NEM Real Time Operations
109362INTER-REGIONAL TRANSFER17/08/2023 05:51:46 PM

Inter-regional transfer limit variation - Tamworth No.1 330 kV SVC- NSW region - 17/08/2023

AEMO ELECTRICITY MARKET NOTICE

Inter-regional transfer limit variation - Tamworth No.1 330 kV SVC- NSW region - 17/08/2023

At 1727 hrs 17/08/2023 there was an unplanned outage of Tamworth No.1 330 kV SVC.

The following constraint set(s) invoked at 1740 hrs 17/08/2023
N-TW_SVC
N-X_LS+TW_SVC

This constraint set(s) contains equations with the following interconnectors on the LHS.
N-Q-MSNP1
NSW1-QLD1

Refer to the AEMO Network Outage Scheduler for further information.

Manager NEM Real Time Operations
109318INTER-REGIONAL TRANSFER14/08/2023 04:17:55 PM

Inter-regional transfer limit variation - SESS CB6611 - SA region - 14/08/2023

AEMO ELECTRICITY MARKET NOTICE

Inter-regional transfer limit variation - SESS CB6611 - SA region - 14/08/2023

At 1630 hrs 14/08/2023 there is a short notice outage of SESS CB6611.

The following constraint set(s) invoked at 1630 hrs 14/08/2023
S-SECB6611_10_BC-2CP

This constraint set(s) contains equations with the following interconnectors on the LHS.
V-SA

Refer to the AEMO Network Outage Scheduler for further information.

Manager NEM Real Time Operations
109310INTER-REGIONAL TRANSFER14/08/2023 11:44:55 AM

Update - Inter-regional transfer limit variation - Georgetown - Comalco No 5 220kV Line - TAS region - 14/08/2023

AEMO ELECTRICITY MARKET NOTICE

Update - Inter-regional transfer limit variation - Georgetown - Comalco No 5 220kV Line - TAS region - 14/08/2023

At 0850 hrs 14/08/2023 there was an unplanned outage of Georgetown - Comalco No 5 220kV Line.

The following constraint set(s) invoked at 0900 hrs 14/08/2023
F-T-CSGO

This constraint set(s) contains equations with the following interconnectors on the LHS.
T-V-MNSP1


Refer to the AEMO Network Outage Scheduler for further information.

Manager NEM Real Time Operations